WR-K SERIES Single Output 60 Watt DC/DC Converter
OUTPUT SPECIFICATIONS:
Voltage Accuracy +/- 1.0%, max.
Voltage Adjustment +/- 10%, max.
Load Regulation(100-25% load) +/- 1%, max.
Line Regulation (HL-LL) +/- 0.5%, max.
Ripple/Noise (20MHz BW) 10 mV RMS, max
75 mV P-P, max.
Temperature Coefficient +/- 0.02%/ degree C, max.
Voltage Stability (24 Hours) +/- 0.05%, max.
Transient Response
+/- 1% Error Band
25% Step Load Change 500 micro sec., max.
Short Circuit Protection Indefinite
Over Voltage Protection 18V
INPUT SPECIFICATIONS:
Input Voltage 9-18 VDC 12V @ 5.0A out
Input Current (no-load) 25mA
Input Current (full load) 6.1A
Efficiency 82%
Output Power 60W
Input Filter Pi Network
Surge Protection Transient Clamp
Reverse Voltage Protection Internal Shunt Diode
GENERAL SPECIFICATIONS:
Isolation Voltage
(input to output) 500VDC, min.
(input to case) 250VDC, min.
Isolation Resistance
(input to output) 10^9 Ohms, min.
(input to case) 10^6 Ohms, min.
Switching Frequency 100KHz
PIN CONNECTIONS:
TERMINAL FUNCTION
1 No Pin
2 – Input
3 – Input
4 + Input
5 + Input
6 Control
7 Case
8 – Output
9 – Output
10 + Output
11 + Output
12 – Sense
13 Trim
14 + Sense
Notes:
- No Minimum Load required for operation
- Remote Sense using pind 12, 14. Connect to remote load and the unit will compensate for up to a 1V drop between converter and load. When not used connect to the Output pins (12=> 8 or 9, 14=> 10 or 11)
- Input reverse voltage protection is provided by an internal shunt diode (provide an external fuse in series with the input)
- TRIM using a 10K resistor:
- To trim up connect 13(trim) to 12(- Sense)
- To trim down connect 13(trim) to 14(+ Sense)
- Remote on/off capable CMOS or open collector TT